Name The Fit The Assembly Must Pass

Ask the product team to identify one fit that controls acceptance. Start with where the fully assembled keychain meets the receiving part.

In this example, a metal tag slides into a rigid presentation fixture. One connector shoulder projects across the side of the tag during insertion.

Show the insertion direction, the fixture faces and the position of the connector on one drawing. Photograph the physical setup with the connector in that position.

Define how much total clearance makes the assembled tag travel as required. Your team can establish that margin by checking real fixture and keychain samples together.

The illustrative buyer sets a minimum of 0.60 mm of total lateral clearance. Separate each side’s minimum if your application requires a centred or aligned installation.

A narrower fixture feature can control the fit later in the travel. During the trial, check the full insertion path with the keychain in its specified orientation.

Draw The Section That Controls Fit

Draw a section through the narrow opening and the widest cross section of the installed keychain. Look perpendicular to the movement so each width has a common direction.

This section has three distances. The fixture gives you space, while the body width and the outward connector projection use that space.

Measure projection from the same body side used for the width. If a supplier instead measures the full assembly, use that one reading directly against the opening.

Put the body’s finished side plane on the section as the reference. From that plane, measure out to the end of the installed connector shoulder.

Call out the condition of each measurement. In the example, the body is finished metal, the connector is installed and the fixture sits in its normal rigid state.

Ask the fixture owner to confirm its narrowest manufactured face. Agree which drawing and measuring location the keychain supplier will use when it records body width.

A keychain and a rigid fixture opening are shown from above with the body's side connector visible.
Read the opening, body width and connector projection from the same section and direction.

Calculate The Smallest Permitted Clearance

Use the smallest permitted opening and the largest permitted occupied width. Subtract the occupied width from the opening to get the lowest clearance your drawing permits.

The Boeing engineering report on tolerance stack analysis distinguishes arithmetic worst case from methods that depend on statistical assumptions. Arithmetic limits fit this buyer’s comparison of permitted boundaries.

Dimension In The SectionDrawing Limits In MillimetresUse In The Worst Case
Fixture Opening25.00 ± 0.30Add minimum 24.70
Finished Tag Body23.00 ± 0.30Subtract maximum 23.30
Connector Projection0.80 ± 0.20Subtract maximum 1.00
Remaining Total Clearance24.70 − 23.30 − 1.000.40 against required 0.60

At the stated sizes, you expect 1.20 mm of clearance. The result at the limits is only 0.40 mm, which is 0.20 mm below the agreed minimum.

A 24.70 mm fixture, 23.30 mm tag and 1.00 mm projection each meet the drawing. Together they still fall short of the functional requirement.

That result predicts a clearance at the stated limits. The handling check establishes whether a particular assembly binds during the actual motion.

A calculation below zero would indicate dimensional interference at those limits. Here the problem is a positive space that is still too small for the agreed handling clearance.

Change One Dimension And Recalculate

Discuss the smallest change that recovers enough margin. In this example, the buyer keeps the fixture and body because they already fit the rest of the programme.

The supplier proposes a different connector with an installed projection of 0.50 ± 0.10 mm. The updated upper limit for the projection is 0.60 mm.

RevisionWorst Case Calculation In MillimetresMargin Against 0.60 Millimetres
Original Connector24.70 − 23.30 − 1.00 = 0.40Short by 0.20
Revised Connector24.70 − 23.30 − 0.60 = 0.80Exceeds minimum by 0.20

Ask how the supplier will hold the projection on the assembled part. The drawing can call out the maximum directly if the joint and finish make that easier to inspect.

Check that the connector change preserves opening, attachment security and normal movement. For metal carabiner keychains, show the actual closed position and the relevant travel.

If a change alters the movement path, redraw the section that governs fit and recalculate. A slot between two fixed planes may need a different check from a hinged opening.

Plan A Physical Check At The Limits

Ask the supplier for a production representative keychain with the revised connector. Confirm the body, finish, installed connector and assembly method match the drawing revision.

Measure the opening, body width and projection on the same setup you will use for the fit trial. Record the actual measurements beside the sample identities.

Start with the real fixture. Ask whether a verified limit fixture or a documented spacer can reproduce the minimum opening for a second test.

If you add a spacer, preserve the original reference face and the entry path. Record where it sits, how it is fixed and which dimension it changes.

Use a sample near the upper assembly width when you can obtain one. An ordinary sample may show the movement works while leaving the worst case calculation untested physically.

Here is an illustrative witness record for the revised build. Attach the dated section drawing and record the names of the people who witnessed the fit.

Record FieldExample Entry
Assembly And DrawingFit sample K18-06, section T2 revision C. Closed connector orientation shown in the approved section.
Limit FixtureBuyer gauge G-04, verified opening 24.70 mm at the controlling section. The original entry path remains clear.
Measured Finished PartBody 23.28 mm plus installed projection 0.59 mm. Total width 23.87 mm.
Calculated Clearance24.70 − 23.87 = 0.83 mm total clearance.
Observed FitInsertion, seating and withdrawal checked with the fixture in its service position.
Joint DispositionBuyer and supplier record the sample result. Approval applies to the stated revision and setup.

Keep the setup repeatable. Mark the insertion direction and align the connector. Check whether the keychain travels, seats and withdraws under the agreed conditions.

Two assembled metal keychains sit next to two openings in a pale green fit gauge block.
Link each physical fit outcome to the exact assembly and fixture that were checked.

The design team’s mechanical tolerance analysis example links a functional assembly problem to contributing dimensions. Use that principle when you write a test other teams can reproduce.

Get Signed Responsibility For Each Interface

Record who owns the fixture revision and who owns each keychain dimension. Give the buyer’s quality contact authority to resolve a disagreement about the functional setup.

The keychain supplier signs the finished body dimension and installed connector projection. The fixture owner signs the opening and measuring faces it supplies.

Have both name the physical samples used for review. Add the measured dimensions, date and result to the section drawing so the approved fit can be traced later.

Add the gauge identification and its latest verification date to the same record. Include an oriented photo so the next shift can reproduce the fixture setup before grading another assembly.

Send an explicit decision to the production team. The approved build includes the connector revision, body drawing and the specific measurement condition that the trial used.

Hold the fit decision if the specimen binds, even after a calculation shows margin. Compare the installation, measurement positions and connector orientation before accepting another result.

Bring the most recent approved section when you ask for a change to custom logo keychains. Reopen the check whenever the revised part uses a contributing dimension differently.

Carry The Check Into The Order

Attach the section drawing, limits and finished sample reference to the line the supplier will build. Keep the drawing date with the revision so teams can identify it quickly.

Agree which checks the factory records on a later run. Where the drawing allows both readings, request the installed width or the two component values that explain it.

If the supplier changes a finish allowance or connector orientation, ask how the original fit calculation changes. Confirm whether the assembly needs a new physical trial before release.

Keep this record for a later order and share the current fixture revision. That gives the receiving team one functional reference when it investigates an unexpected tight fit.

Frequently Asked Questions

Can I Use The Full Assembled Width?

Specify the full maximum width in the controlling orientation and inspect the finished assembly directly. Keep the body and connector dimensions on the drawing. They help the factory investigate a failed fit.

What If The Fixture Flexes In Normal Use?

Agree how the fixture is supported and how much movement is acceptable in real use. The example uses a rigid opening. A flexible opening needs a representative check under the conditions you expect.

Should I Add A Separate Finish Thickness?

First check whether the dimension already applies after finishing. For a bare part dimension, ask the supplier how the finish changes the final size. Then agree how to control the finished dimension.

Can I Reuse A Fit Check For A Different Connector?

Compare every affected dimension and movement with the approved build. If the new connector changes the outside envelope or path, confirm the revised calculation and agree the sample check before release.